    The system temperature for interim correlator boards 3 and 4 increased by about 3 K sometime around 21jun11 (we're not exactly sure when the problem first occurred). After trouble shooting we found that the +5 analog voltage for halfband filters 3 and 4 (in the same chassis) had a 2V repetitive dropout. We replaced the power supply and the system started to work.
    The halfband configuration is:

    We took some data before and after the changes. The setup was:

    The data taken before the power supply was fixed (.ps) (.pdf):

    The data taken after the power supplied was repaired (.ps) (.pdf):
The data taken after the power supplied was repaired repeated (.ps) (.pdf):