Log for 090419 Observer: Betsey Adams System Configuration: a2010_az180_2009.conf CIMA version 3.1.03 2008-1-20 13:50 "Smart" File: /share/pserverf.sda3/wappdata/wapp.20090419.a2010.****.fits /share/pserverf.sda3/wappdata/wapp.20090420.a2010.****.fits **** LST fits Scan calscan Source Pattern Start coords. ang time loop calmode 0925 0019 910900188 910900189 drift89p1 fixAZdr 092500+213206 19 600 99 loopend fits file ok 0935 0020 910900190 910900191 0945 0021 910900192 910900193 0955 0022 910900194 910900195 extrapolating and interpolating warnings 1006 0023 910900196 910900197 1016 0024 910900198 910900199 1026 0025 910900200 910900201 1036 0026 910900202 910900203 1046 0027 910900204 Failed WAPP-3 failure, restart WAPPS 1048 0028 910900205 910900206 fits file ok 1058 0029 910900207 910900208 1108 0030 910900209 910900210 1118 0031 910900211 910900212 1128 0032 910900213 910900214 1138 0033 910900215 910900216 1148 0034 910900217 910900218 1158 0035 910900219 910900220 1208 0036 910900221 910900222 1218 0037 910900223 910900224 1229 0038 910900225 910900226 1239 0039 910900227 910900228 fits file ok 1249 0040 910900229 910900230 1259 0041 910900231 910900232 1309 0042 910900233 910900234 1319 0043 910900235 911000001 1329 0000 911000002 911000003 fits file ok 1339 0001 911000004 911000005 1349 0002 911000006 911000007 1400 0003 911000008 911000009 1410 0004 911000010 911000011 1420 0005 911000012 911000013 1430 0006 911000014 911000015 1440 0007 911000016 911000017 1450 0008 911000018 911000019 1500 0009 911000020 911000021 1510 0010 911000022 911000023 fits file ok 1520 0011 911000024 911000025 1531 0012 911000026 Aborted END LST: 1531 Notes: Running the new version of CIMA 3.1.03 "Smart" At AZ=540 TOGS not run at start - failing on adjusting WAPP power Wapp-1 is failing on adjust power step Restarting WAPPS and restarting CIMA both fail to fix problem Start of night lost - WAPP-1 fixed in correlator room by disconnecting half-band (?) filter Problem was with filter (not needed for ALFALFA), resulted in cutting power to WAPP-1 Beam 6B dead FAA radar on TOGS run at end WAPP error messages: Start of night: 2009-Apr-19 19:22:57 ERROR end_wait_seconds: ERROR timed out while waiting for adjust WAPP power! 2009-Apr-19 19:23:02 ERROR end_wait_seconds: ERROR timed out while waiting for stopping WAPPs! 2009-Apr-19 19:23:02 ERROR finish_task: ERROR failed adjusting: WAPP power 2009-Apr-19 19:23:02 ERROR finish_task: ERROR failed adjusting: WAPP power levels 2009-Apr-19 19:23:03 ERROR WAPP=1-wappcon: ERROR the WAPP never aborted! 2009-Apr-19 19:32:44 ERROR WAPP=1-wappcon: ERROR ignoring command 'ADJUSTPOWER' since WAPP1 is busy! 2009-Apr-19 19:32:48 ERROR end_wait_seconds: ERROR timed out while waiting for adjust WAPP power! 2009-Apr-19 19:33:17 ERROR WAPP=1-adjust_power: ERROR overflow when using first 'EDT_NEXTBUF'! WAPP-3: 2009-Apr-19 21:20:30 ERROR wapp_failed: ERROR WAPP-3 failed to complete2009-Apr-19 21:20:33 WARNING WAPPDATA-flush_pending: WARNING WAPPDATA flushing 24 dumps! its current task! 2009-Apr-19 21:20:31 ERROR WAPP=3-read_timeout: ERROR time-out while waiting for data from the correlator! 2009-Apr-19 21:20:31 ERROR WAPP=3-start_spectra: ERROR failed to read spectral line data! 2009-Apr-19 21:20:31 PROBLEM WAPP=3-start_spectra: Reason: Connection timed out! 2009-Apr-19 21:20:31 ERROR WAPP=3-start_spectra: ERROR the correlator has failed to start!