| C1 | from | to | description |
| 1 | PA.1 | P8.1 | vertex datataking ethernet rx @ pntp1 |
| 2 | PA.2 | P8.2 | vertex datataking ethernet tx @ pntp1 |
| 3 | ocu.rx | lcu.tx | lcu to ocu rs422 link |
| 4 | ocu.tx | lcu.rx | lcu to ocu rs422 link |
| 5 | PB.11 (PA.3) | P8.5 | pnt crate irig board to lcu irig board. (PB.11 till PA.3 fixed)16feb03 |
| 6 | PA.4 | P6.1 | turret 485 link. rx @ pnt |
| 7 | PA.5 | P6.2 | turret 485 link. tx @ pnt |
| 8 | PA.6 | P6.3 | tertiary ethernet (datataking). rx@pnt |
| 9 | PA.7 | P6.4 | tertiary ethernet (datataking). tx@pnt |
| 10 | PA.8 | P6.5 | 1 pps for turret and tertiary (splitter in B13) |
| 11 | free | free | was platform ethernet RP1.6 to RP2.12 this fiber has 5db more loss than fiber 12 and 13 (so we switched to 13) |
| 12 | PA.10 | RP2.11rx | platform ethernet RP1.5 to RP2.11 |
| 13 | PA.9 | RP2.11tx | platform ethernet RP1.5 to RP2.11 (was c1-11) |
| 14 | PB.7 | P6.6 | tertiary 1pps (install then remove splitter B13). |
| 15 | nd1 | P4.5 | noise diode ttl driver pol a/ |
| 16 | nd2 free?? |
P4.6 | noise diode ttl driver polb (note nd1 drives both). |
| 17 | hpib | P4.1 | hpib extender for datataking gpib |
| 18 | hpib | P4.3 | hpib extender for datataking gpib. |
| 19 | gregorian monoplexor driver. | ||
| 20 | gregorian monoplexor ack. | ||
| 21 | ch1 noise pulse llr1 | ||
| 22 | ch1 noise poulse llr2 | ||
| 23 | ch1 monoplexor driver | ||
| 24 | ch1 monoplexor ack | ||
| 25 | Note |
dome |
dome video cameras. From controller at operators desk to
video box in tx room dome. |
| 26 | free |
was hpib seti rx @ ctrlroom | |
| 27 | free |
was hpib seti tx @ ctrlroom | |
| 28 | 430con | p6.12 | 430 pwr meter for greg dome |
| 29 | 430con |
b7.? |
trigger for ch power meter |
| 30 | free |
(was ch1 overspeed indicator) | |
| 31 | 430Con |
p6.10 |
430 dome power meter |
| 32 | 430Con |
p6.11 |
430 dome power meter .. note c1.28,31,32.. don't know
which is ethernet and which is gate yet... |
| 33 | Note |
top dome |
dome wheel switches Note: from dome wheel box ctrl room above irig display |
| 34 | free |
was free | |
| 35 | 430con |
b7.6 |
ch1 power meter ethernet |
| 36 | 430con |
b7.7 |
ch power meter ethernet |
| C2 #'s @B2A |
description |
From |
| 1 |
||
| 2 |
||
| 3 |
||
| 4 |
||
| 5 |
crowbarTrigFORcvA |
power supply B3 |
| 6 |
crowbarTrigFORcvB |
power supply B3 |
| 7 |
||
| 8 |
||
| 9 |
tti communications for dome. |
B1,9.5 to B2a,2-9. not sure
the number at pwrsupply building |
| 10 |
tti communicactions for dome |
B1,9.6 to B2a,2-10. not sure
the number at the pwrsupply building |
| C3 | Description | From |
| 1 | pcWeather station to weather station. | B1- P1 |
| C5 | From | To | Description |
| 1 | pb2 | b7-td12 | rs485 rx(master in pntcrate) to tx in td12 |
| 2 | pb3 | b7-td12 | rs485 tx master in pntcrate to rx in td12 |
| 3 | pb4 | b7-td12 | 1 second tick for tiedowns 12 |
| 4 | pb (black) |
b7-td12 |
1 sec tick for tiedown 8 |
| 5 | pb (yellow) |
b7-td12 |
1 sec tick for tiedown 4 |
| 6 | |||
| 7 | td8 tx | ||
| 8 | td8 rx | ||
| 9 | t4tx | ||
| 10 | t4rx | ||
| C5A | From |
To | Description |
| 1 | td12 dymec(bottom) | td4 | rs485 from td12 to td4 (not user which is tx/rx) |
| 2 | td12 dymec(bottom) | td4 | rsf85 from td12 to td4 |
| 3 | td12-5 Originally from C5.5 |
td4tick | 1 second tick for td4 |
| 4 | td4 dymec bottom | td8 via 5B.1 |
from td4, to to B7-12 then over to td8 via 5B1 this is how the 485 goes from td4 to td8 |
| 5 | td4 dymec bottom | td8 via 5B.2 |
see above |
| 6 | optical splitter B7-12 | td8tick | I'm not sure this really goes from td12 to 4 to 8... My guess is it goes directly from the optical splitter in td12 to td8 via C5B. |
| 7 | |||
| 8 | |||
| 9 | c5.9 |
td4 |
etherent rx at td4 |
| 10 | c5.10 |
td4 |
ethernet tx at td4 |
| 11 | |||
| 12 |
| C5B | From |
To | Description |
| 1 | c5a:4 td4 dymec(bottom) | td8 | rs485 from td4 to td8.is looped back on c5a cable
from td4 |
| 2 | c5a:5 td4 dymec(bottom) | td8 | rs485 from td4 to td8.is looped back on c5a cable from td4 |
| 3 | td12-4 Originally from C5.4 |
td8tick | 1 second tick for td8 |
| 4 | |||
| 5 | |||
| 6 | |||
| 7 | |||
| 8 | |||
| 9 | c5.7 |
td8 |
ethernet rx at td8 |
| 10 | c5.8 |
td8 |
ethernet tx at td8 |
| 11 | |||
| 12 |
| c7 |
From |
To |
Description |
| 1 |
|||
| 2 |
|||
| 3 |
|||
| 4 |
|||
| 5 |
|||
| 6 |
b1.34 |
ch pwrmeter |
ch pwr meter ethernet |
| 7 |
b1.35 |
ch pwrmeter |
ch pwr meter ethernet |
| 8 |
|||
| 9 |
|||
| 10 |
|||
| 11 |
|||
| 12 |
| C8 | Description | From |
| 1 | datataking ethernet (rx @ pntp1) | C1.1 |
| 2 | datataking ethernet (tx @ pntp1) | C1.2 |
| 3 | ocu rs 422 link (tx @lcu) | C1.3 |
| 4 | ocu rs422 link (rx @ lcu) | C1.4 |
| 5 | irig signal | C1.5 |
| 6 | platform ethernet (rx @ lcu) | RP2.tx7 |
| 7 | platform ethernet (tx @ lcu) | RP2.rx7 |
| 8 | spare | |
| 9 | ||
| 10 | ||
| 11 | ||
| 12 |
| C9 |
Description |
From |
| 1 |
tti transnet communications
for power supply tti modules Tested 16nov11, tx,rcv meter -15.4 dbm |
sband tti optic extender (by
sband console) |
| 2 |
tti transnet communications
for power supply tti modules Tested 16nov11. tx,rcv meter -15.6 dbm |
sband tti optic extender (by sband console) |
| 3 |
||
| 4 |
||
| 5 |
tti transnet
communications for dome tti modules tested 16nov11: B1 to pwrSup patch: -16.1dbm B1 to B2a dome : -17.1 dbm B1 to ttiOpticExtender sband cab:-17.4dbm |
from sband console. Goes to
patch panel in power supply building and then up to dome box 2a #2-9 |
| 6 |
tti transnet communications
for dome tti modules tested 16nov11. tx,rcv meter B1 to pwrSup patch: -15.6 dbm B1 to B2aDome : -17.1 dbm B1 to ttiOpticExtender sband cab:-17.7 dbm |
from sband console. Goes to
patch panel in power supply building and then up to dome box
2a #2-10. |
| 7 |
||
| 8 |
||
| 9 |
||
| 10 |
||
| 11 |
||
| 12 |
| C11 multi mode 1-12 buffer 3 |
From |
To |
Description |
| 1 |
|||
| 2 |
|||
| 3 |
|||
| 4 |
|||
| 5 |
B11.5 |
B?.5 |
alfa temps |
| 6 |
B11.6 |
B?.6 |
alfa temps |
| 7 |
B11.7 |
b?.7 |
alfa motor control |
| 8 |
B11.8 |
B?.8 |
alfa motor control |
| 9 |
B11.9 |
B |
alfa on/off switch |
| 10 |
|||
| 11 |
|||
| 12 |
| rp2tx | Tx | Rx |
| 12 | P4.8 rot flr moveable dewar monitoring |
P4.7 rot flr moveable dewar monitoring. |
| 11 | B2.13->B1.13->RP1.5 (downstairs) | B2.12->B1.12->RP1.5 |
| 10 | P6.6 ->B13R.6-> tertiary(notused) | P6.9->B13R.9->tertiary(not used) |
| 9 | P6.10->B13R.10->B13L.1->B14.1 | P6.11->B13R.11->B13L.2->B14.2 servPlatform |
| 8 | free | |
| 7 | C8.6 -> vertex shelter | C8.7 -> vertex shelter |
Notes.. PC6 doesn't have enough fibers for the platform
ethernet to go to tertiary and the turret fixed
floor. We'll probably just run it to the tertiary. You can undo
the jumper in B13 if you want it at the turret fixed floor.
| P4 | description | From |
| 1 | hpib extender tx | C1.17 |
| 2 | bad | |
| 3 | hpib extender rx | C1.18 |
| 4 | ?? | |
| 5 | noise diode ttl driver (not used??) | C1.15 |
| 6 | noise diode ttl driver (not used??) | C1.16 |
| 7 | platform ethernet (rx @ floor) | RP2.tx12 |
| 8 | platform ethernet to lcu (tx @ floor) | RP2.rx12 |
| PC 6 | description | B13R |
| 1 | Turret 485. Tx@tur from B2. 6 | 1 |
| 2 | Turret 485. Rx @ tur from B2.7 | 2 |
| 3 | tertiary ethernet (datataing) tx at ter. from B2.8 | 3 |
| 4 | tertiary ethernet (datataking) rx at ter. from B2.9 | 4 |
| 5 | 1 pps for tur and ter. (splitter in box 13) from B2.10 | 5 |
| 6 | platform ethernet (tur/ter) rcv From RP2.tx10 | 6 |
| 7 | bad cable (no connection B13.7 back) | 7 |
| 8 | bad cable (cable connected B13.8 back but no signal). | 8 |
| 9 | platform ethernet (tur/ter) tx. From RP2.rx10 | 9 |
| 10 | 430 dome power meter ethernet |
10 |
| 11 | 430 dome power meter ethernet |
11 |
| 12 | 430 pwr meter gregorian from B2.28 | 12 |
| P7 | Description | From |
| 1 | platform ethernet (rx @ servPlat) | RP2.tx9->P6.10->B13R.10->B13L.1->B14.1 |
| 2 | platform ethernet (tx @ servPlat) | RP2.rx9->P6.11->B13R.11->B13L.2->B14.2 |
| 3 |
| description | route | |
| hilltop rfi monitor gpib | gpib fiber extender in pntcrate rack ->to PA11,13 -> to controlroom ->to M1,2 inputs fiber Junction box below junction box B1 -> junction box below water pipe patch box rightmost 2 input (looking from above).This junction box is behind the racks in the control room--> Up to rfi shack on hilltop. |