S-High Receiver
|
Basic Information | Calibration & Beam Parameters RFI Situation Recent Events Receiver History Technical Description Contact Info |
| Frequency Range (GHz): |
3.0 - 4.0
|
|
Name and Number:
sbh, sbh1_2, and 8, 81 (*)
|
Measured Sensitivity (K/Jy):
|
~ 7 - 10 (**)
|
Measured System Temp (K):
|
~ 27 - 29 (**)
|
Native Polarization:
|
Dual Linear(***)
|
Beam Size (at 3.3 GHz):
|
~ 85 arcsec (**)
|
Available Filters:
|
No RF filters at present
|
Warnings and Important Notes:
|
None
|
| |
*** Can be circularized by using the 10-GH upconversion IF/LO path and a hybrid (More Info)
2. Calibration & Beam Parameters:
| Gain and Tsys | Cal Values | Beam Maps | Polarization | Misc. Info |
Polarization properties of this Rx has not been determined yet. However, here
is an useful documents
The Mueller
Matrix Parameters for Arecibo's Receiver Systems (Not including this
Reciver) by C. Heiles et
al (~5MB, PS file)
A short introduction to digital
spectropolarimetry written be Carl Heiles can be found
in this PDF file
More information on calibration techniques can be found in Chris
Salter's "Note relevant
to Spectral Line User's"
Yet to be fully characterized.
It has been decided in April 2005 to keep this Rx uncooled while NOT in use (due to low usage at this time and high demand on cryogenics). It can be cooled down with 2 days' notice.
The Receiver was installed in 2001. Currently, it is kept at room temperature, but can be cooled (in 2 days) when needed.
Technical details are only avaiable on our internal pages (click on the appropriate links on top of the RX table. If you arelooking for any specific information/diagram etc, please see below.
For further information on this receiver, please contact T. Ghosh at